... four lights are required , the emergency lighting shall be provided through circuits separated from the general ... four feet each in width shall be required for occupancies of three hundred to four hundred fifty persons . Such exits or ...
... four lights are required , the emergency lighting shall be provided through circuits separated from the general ... four feet each in width shall be required for occupancies of three hundred to four hundred fifty persons . Such exits or ...
Page 657
... four times the diameter of the web bar ; 4. A length of embedment sufficient to develop the stress in the stirrup by ... four - way ยง C26-493.0 Two- and four - way flat slab systems with square Two and or rectangular panels . - a ...
... four times the diameter of the web bar ; 4. A length of embedment sufficient to develop the stress in the stirrup by ... four - way ยง C26-493.0 Two- and four - way flat slab systems with square Two and or rectangular panels . - a ...
Page 686
... four inch timbers , and sills shall be at least four by six inches or three by eight inches . Mortise and tenon framing shall be used only with timbers at least four by six inches ( nominal ) . All structural parts of the wood framework ...
... four inch timbers , and sills shall be at least four by six inches or three by eight inches . Mortise and tenon framing shall be used only with timbers at least four by six inches ( nominal ) . All structural parts of the wood framework ...
Contents
Table of Sections With Page References | xxii |
Chapter 928 | xxxvii |
Chapter 929 | 1 |
64 other sections not shown
Other editions - View all
Common terms and phrases
amount application approved assessment avenue beams board of estimate borough president building car safety certificate charter city collector column combustible commissioner comply comptroller concrete construction corporation counsel counterweight court designed device distance dollars dumbwaiter duty East One hundred East river elevator enclosure exit factor of safety Fahrenheit fee title fifty filed fire resistive rating fireproof floor fund gypsum height hoistway doors inches incombustible issued landing least license live load load located masonry material maximum means of egress ment metal notice one-half operation owner paid partitions payment pension permit person pounds per square premises proceeding real property reinforcement retirement roof safety sidewalk square inch stairways steel storage street structure SUB-ARTICLE subdivision superintendent tax lien taxicab thence therein thereof thereto tion transfer of tax unlawful vomitories walls width