Page 648
... beams and slabs shall be the clear span plus the effective depth of beam or slab , but shall be within the distance between centers of the supports . b . The span length for continuous or restrained beams built to act integrally with ...
... beams and slabs shall be the clear span plus the effective depth of beam or slab , but shall be within the distance between centers of the supports . b . The span length for continuous or restrained beams built to act integrally with ...
Page 684
... beams over eight feet long and trimmer and header beams shall be hung in approved metal stirrups or hangers and shall be spiked unless supported on a wall or girder . e . It shall be unlawful to notch or cut wood beams , joists or ...
... beams over eight feet long and trimmer and header beams shall be hung in approved metal stirrups or hangers and shall be spiked unless supported on a wall or girder . e . It shall be unlawful to notch or cut wood beams , joists or ...
Page 796
... beams shall be assumed to be equal to the weight of all apparatus resting on such beams plus twice the maximum load suspended from such beams . 2. The load resting on such beams shall include the complete weights of machine , sheaves ...
... beams shall be assumed to be equal to the weight of all apparatus resting on such beams plus twice the maximum load suspended from such beams . 2. The load resting on such beams shall include the complete weights of machine , sheaves ...
Contents
Table of Sections With Page References | xxii |
Chapter 928 | xxxvii |
Chapter 929 | 1 |
64 other sections not shown
Other editions - View all
Common terms and phrases
amount application approved assessment avenue beams board of estimate borough president building car safety certificate charter city collector column combustible commissioner comply comptroller concrete construction corporation counsel counterweight court designed device distance dollars dumbwaiter duty East One hundred East river elevator enclosure exit factor of safety Fahrenheit fee title fifty filed fire resistive rating fireproof floor fund gypsum height hoistway doors inches incombustible issued landing least license live load load located masonry material maximum means of egress ment metal notice one-half operation owner paid partitions payment pension permit person pounds per square premises proceeding real property reinforcement retirement roof safety sidewalk square inch stairways steel storage street structure SUB-ARTICLE subdivision superintendent tax lien taxicab thence therein thereof thereto tion transfer of tax unlawful vomitories walls width