Boysen Dam and Powerplant: Constructed 1947-19521957 - Boysen Dam - 266 pages |
From inside the book
Results 1-5 of 80
Page
... electrical equip- ment . Part III is devoted to contract administration and Part IV to construction operations . This technical record was prepared in the Commissioner's Office , Denver , under the direction of the Assistant ...
... electrical equip- ment . Part III is devoted to contract administration and Part IV to construction operations . This technical record was prepared in the Commissioner's Office , Denver , under the direction of the Assistant ...
Page v
... ELECTRICAL EQUIPMENT 78. Generators and excitation systems 117 ( a ) Ratings and characteristics 117 ( b ) Construction details 119 ( c ) Excitation system 121 79. Generator - voltage power and associated equipment 122 ( a ) Generator ...
... ELECTRICAL EQUIPMENT 78. Generators and excitation systems 117 ( a ) Ratings and characteristics 117 ( b ) Construction details 119 ( c ) Excitation system 121 79. Generator - voltage power and associated equipment 122 ( a ) Generator ...
Page ix
... Electrical installation ( a ) Wiring ( b ) Station - service transformers 210 210 210 211 211 213 ( c ) Switchgear ( d ) Power and distribution boards 168. Communication equipment 169. Switchyard equipment 170. Energizing equipment 171 ...
... Electrical installation ( a ) Wiring ( b ) Station - service transformers 210 210 210 211 211 213 ( c ) Switchgear ( d ) Power and distribution boards 168. Communication equipment 169. Switchyard equipment 170. Energizing equipment 171 ...
Page xi
... electrical installation 137 45 Electrical installation -- Single line conduit and circuit diagram 140 46 General view of Boysen Dam and Powerplant from above left abutment , showing reservoir area before start of water storage 144 47 ...
... electrical installation 137 45 Electrical installation -- Single line conduit and circuit diagram 140 46 General view of Boysen Dam and Powerplant from above left abutment , showing reservoir area before start of water storage 144 47 ...
Page 19
... electric and hand - operated pumps , control valves , air trap , and manifold system . The incoming plastic tubing from the embankment is joined to the 1 / 4 - inch standard brass pipe in the manifold system by compression - type ...
... electric and hand - operated pumps , control valves , air trap , and manifold system . The incoming plastic tubing from the embankment is joined to the 1 / 4 - inch standard brass pipe in the manifold system by compression - type ...
Contents
147 | |
153 | |
156 | |
161 | |
162 | |
164 | |
164 | |
165 | |
60 | |
66 | |
73 | |
79 | |
88 | |
95 | |
101 | |
111 | |
114 | |
122 | |
128 | |
136 | |
143 | |
170 | |
172 | |
173 | |
175 | |
177 | |
180 | |
189 | |
195 | |
203 | |
203 | |
211 | |
233 | |
Common terms and phrases
000 second-feet acre-feet anchor axis backfill Bighorn River Boysen Dam Boysen Powerplant Boysen Reservoir Brass breakers bridge Bronze bulkhead gate channel circuit circuit breakers compressor concrete construction contractor copper crest cubic foot deck designed diorite discharge diversion tunnel downstream draft tube drawing embankment equipment excavation flood foundation gate structure girders Government camp Gray iron Gros Ventre grout grout holes header hoist holes were drilled hydraulic inlet wall installed leaf left abutment load located material maximum normal operating outlet pipe penstock percent pier piezometer pounds per square powerhouse pressure pump radial gates railroad tunnel reinforced relocated reservoir water reservoir water surface right abutment ring RING SEAL riprap river rock roof sandstone SCALE OF FEET seal SECTION SHOSHONI side slope spillway square inch steel stilling basin storage surge tank switchyard tailwater tank Thermopolis transformer trashrack structure turbine unit upstream valve vertical zone