Platoro Dam: Constructed 1949-19511954 - Dams - 71 pages |
From inside the book
Results 1-5 of 26
Page i
... Zone 2 ( c ) Other zones 17. Field modifications B. Spillway and Outlet Works 18. Spillway 13 19 . Diversion plan 13 20 . Outlet works 13 21. Hydraulic design of outlet works 18 22 . Structural design of outlet 18 23 . Outlet works ...
... Zone 2 ( c ) Other zones 17. Field modifications B. Spillway and Outlet Works 18. Spillway 13 19 . Diversion plan 13 20 . Outlet works 13 21. Hydraulic design of outlet works 18 22 . Structural design of outlet 18 23 . Outlet works ...
Page iii
... ( zone 1 ) C. Embankment 44 48 48 50 50 50 50 59. Sand and gravel fill ( zones 2 and 4 ) 60. Tamped - earth fill ( special compaction ) 61. Rock and cobble fill ( zone 3 ) 62. Riprap on upstream slope 63. Special zones at the top of the ...
... ( zone 1 ) C. Embankment 44 48 48 50 50 50 50 59. Sand and gravel fill ( zones 2 and 4 ) 60. Tamped - earth fill ( special compaction ) 61. Rock and cobble fill ( zone 3 ) 62. Riprap on upstream slope 63. Special zones at the top of the ...
Page v
... zone 2 and zone 4 material in the upstream part of the river section 49 25. Loading zone 1 material in a pothole downstream from station 14 + 00 49 26. Large pneumatic tamping machine being used to compact zone 1 material on right ...
... zone 2 and zone 4 material in the upstream part of the river section 49 25. Loading zone 1 material in a pothole downstream from station 14 + 00 49 26. Large pneumatic tamping machine being used to compact zone 1 material on right ...
Page 1
... zone is uncertain . Other minor faulted zones probably exist but are not apparent . Two holes were drilled to locate the top of sound rock for the inlet of the diversion tunnel . The tunnel outlet was located in a steep bluff of exposed ...
... zone is uncertain . Other minor faulted zones probably exist but are not apparent . Two holes were drilled to locate the top of sound rock for the inlet of the diversion tunnel . The tunnel outlet was located in a steep bluff of exposed ...
Page 3
... zone is uncertain . Other minor faulted zones probably exist but are not apparent . Two holes were drilled to locate the top of sound rock for the inlet of the diversion tunnel . The tunnel outlet was located in a steep bluff of exposed ...
... zone is uncertain . Other minor faulted zones probably exist but are not apparent . Two holes were drilled to locate the top of sound rock for the inlet of the diversion tunnel . The tunnel outlet was located in a steep bluff of exposed ...
Common terms and phrases
5-Foot High-Pressure acre-feet andesite Bolt bulldozed butterfly valves channel cofferdam completed conduit Conejos River contract cost cubic feet cubic yards cutoff trench dam and dike dam embankment dam foundation Denver dike section discharge drain emergency gate end-dump trucks engineer equipment excavation fault feet per second Figure fill zone flange flow fractured gate chamber Government camp grout cap Grout holes haul high-pressure gate impervious material inches inlet installation joints July Aug Sept June 21 laboratory leaf-Class left abutment load located main dam maximum Metal metalwork mixer moisture Order for changes outlet pipe outlet tunnel PARTIAL RUNOFF percent placed placement plates Platoro Dam pumpcrete machine reservoir right abutment Rio Grande Compact RIO GRANDE COUNTY riprap ROCK BORROW AREA rockfill SAN LUIS VALLEY separation plant SLIDE ROCK BORROW specifications spillway bridge steel pipe support rings talus tests trashrack structure unit valve house zone 1 material
Popular passages
Page 18 - ... PARTS 151. Character of Structure.— The structure is to be of the skeleton, curtain-beam type, resting on I-beam footings or grillages. The building is to be (18) stories high, with a basement story and a (flat) (mansard) (pointed) (hipped) roof. 152. Floor Loading.— The floors are to be calculated for a live load of (100) pounds per square foot, and a dead load of (50) pounds per square foot. The roof is to be calculated for a live load of (50) pounds per square foot, and a dead load of...
Page 22 - Specifications for Low and Intermediate Tensile Strength Carbon-Steel Plates of Flange and Firebox Qualities (Plates 2 in. and Under in Thickness) (ASTM Designation: A 285),' or Tentative Specifications for Low and Intermediate Tensile Strength Carbon-Steel Plates of Structural Quality (Plates 2 in.