... truck load and was placed such that its width may be increased easily at a later date if desired . 19. Diversion Plan . - During construction of the outlet tunnel the river was permitted to flow in its natural channel . Flow was to be ...
... truck load and was placed such that its width may be increased easily at a later date if desired . 19. Diversion Plan . - During construction of the outlet tunnel the river was permitted to flow in its natural channel . Flow was to be ...
Page 18
... truck loading plus a 10 percent impact load . When the discharge valves are repaired or replaced , it is desirable and pro- vision is made to load or unload them directly onto or from a truck in the valve house . The roof slab is ...
... truck loading plus a 10 percent impact load . When the discharge valves are repaired or replaced , it is desirable and pro- vision is made to load or unload them directly onto or from a truck in the valve house . The roof slab is ...
Page 31
... truck driver , and four laborers . This force was respon- sible for performance of administrative activities and functions of the office , performing routine office duties such as filing , costkeeping , personnel and finance operations ...
... truck driver , and four laborers . This force was respon- sible for performance of administrative activities and functions of the office , performing routine office duties such as filing , costkeeping , personnel and finance operations ...
Page 32
... one bulldozer operator , two truck drivers , and 18 labor- ers . Wage rates ranged from $ 1 . 20 per hour for laborers to $ 2.24 per hour for electri- cians and plumbers . Because of a lack of housing and the isolated location 32.
... one bulldozer operator , two truck drivers , and 18 labor- ers . Wage rates ranged from $ 1 . 20 per hour for laborers to $ 2.24 per hour for electri- cians and plumbers . Because of a lack of housing and the isolated location 32.
Page 34
... trucks , required the services of from one to three men in addition to a motor grader to keep them cleared . The Bureau did not have a full time inspector during the entire period of construction because procurement of personnel for ...
... trucks , required the services of from one to three men in addition to a motor grader to keep them cleared . The Bureau did not have a full time inspector during the entire period of construction because procurement of personnel for ...
Common terms and phrases
48-inch butterfly valves acre-feet andesite axis Bolt bulldozed butterfly valves cofferdam completed Concrete grout conduit Conejos River contract cost cubic feet cubic yards cutoff trench dam and dike dam embankment dam foundation dike section discharge drain emergency gate end-dump trucks engineer equipment excavation fault fault gouge feet per second Figure fill zone flange flow fractured gate chamber Government camp grout cap Grout holes haul impervious material inches installation joints July Aug Sept June 21 laboratory leaf-Class left abutment load located main dam maximum Metal metalwork mixer moisture Order for changes outlet pipe outlet tunnel PARTIAL RUNOFF percent placed placement plates Platoro Dam pounds per square pumpcrete machine right abutment Rio Grande Compact RIO GRANDE COUNTY riprap ROCK BORROW AREA rockfill SAN LUIS VALLEY separation plant SLIDE ROCK BORROW specifications spillway bridge support rings talus tests trashrack structure unit valve house zone 1 material
Popular passages
Page 18 - ... PARTS 151. Character of Structure.— The structure is to be of the skeleton, curtain-beam type, resting on I-beam footings or grillages. The building is to be (18) stories high, with a basement story and a (flat) (mansard) (pointed) (hipped) roof. 152. Floor Loading.— The floors are to be calculated for a live load of (100) pounds per square foot, and a dead load of (50) pounds per square foot. The roof is to be calculated for a live load of (50) pounds per square foot, and a dead load of...
Page 22 - Specifications for Low and Intermediate Tensile Strength Carbon-Steel Plates of Flange and Firebox Qualities (Plates 2 in. and Under in Thickness) (ASTM Designation: A 285),' or Tentative Specifications for Low and Intermediate Tensile Strength Carbon-Steel Plates of Structural Quality (Plates 2 in.