Platoro Dam: Constructed 1949-19511954 - Dams - 71 pages |
From inside the book
Results 1-5 of 15
Page
... Drainage 39.7 square miles ་ Maximum flood : 1,380 cubic feet per second ( 1949 ) Reservoir : Area : 950 acres Total storage ( including superstorage ) : 67 , 800 acre - feet at elevation 10 , 042.0 Irrigation and flood control storage ...
... Drainage 39.7 square miles ་ Maximum flood : 1,380 cubic feet per second ( 1949 ) Reservoir : Area : 950 acres Total storage ( including superstorage ) : 67 , 800 acre - feet at elevation 10 , 042.0 Irrigation and flood control storage ...
Page
... Drainage Maximus area no 1 , 380 cubic feet per second ( 1949 ) 39.7 square miles Reservoir : Area : 950 acres Total storage ( including superstorage ) : 67,800 acre - feet at elevation 10 , 042.0 Irrigation and flood control storage ...
... Drainage Maximus area no 1 , 380 cubic feet per second ( 1949 ) 39.7 square miles Reservoir : Area : 950 acres Total storage ( including superstorage ) : 67,800 acre - feet at elevation 10 , 042.0 Irrigation and flood control storage ...
Page 5
... draining , river - deposited sand and gravel , with only a small amount of fines . Maximum size of the gravel was about 2 inches . Because the depth of exploration holes was restricted by high water table , quantity estimates were ...
... draining , river - deposited sand and gravel , with only a small amount of fines . Maximum size of the gravel was about 2 inches . Because the depth of exploration holes was restricted by high water table , quantity estimates were ...
Page 7
... drain any reservoir tributary to the Rio Grande River , such provisions were planned for Platoro Dam . As actually constructed the total capacity of the reservoir is 67 , 800 acre - feet . Con- servation storage is 60,000 acre - feet at ...
... drain any reservoir tributary to the Rio Grande River , such provisions were planned for Platoro Dam . As actually constructed the total capacity of the reservoir is 67 , 800 acre - feet . Con- servation storage is 60,000 acre - feet at ...
Page 8
... Drain Retaining wall Valve house 9950- El . 9900.0 Axis of dam N60 ° 00'W PRC Sta 7 + 5305 5 Si El 9950.0 9950 FA 59 ° 30 ' 210.00 ' R. T = 120.02 ' L = 218.08 100,000 Cutoff french Concrete grout cap . 9950- 9925- RIVER Tunnel Crest El ...
... Drain Retaining wall Valve house 9950- El . 9900.0 Axis of dam N60 ° 00'W PRC Sta 7 + 5305 5 Si El 9950.0 9950 FA 59 ° 30 ' 210.00 ' R. T = 120.02 ' L = 218.08 100,000 Cutoff french Concrete grout cap . 9950- 9925- RIVER Tunnel Crest El ...
Common terms and phrases
48-inch butterfly valves acre-feet andesite axis Bolt bulldozed butterfly valves cofferdam completed Concrete grout conduit Conejos River contract cost cubic feet cubic yards cutoff trench dam and dike dam embankment dam foundation dike section discharge drain emergency gate end-dump trucks engineer equipment excavation fault fault gouge feet per second Figure fill zone flange flow fractured gate chamber Government camp grout cap Grout holes haul impervious material inches installation joints July Aug Sept June 21 laboratory leaf-Class left abutment load located main dam maximum Metal metalwork mixer moisture Order for changes outlet pipe outlet tunnel PARTIAL RUNOFF percent placed placement plates Platoro Dam pounds per square pumpcrete machine right abutment Rio Grande Compact RIO GRANDE COUNTY riprap ROCK BORROW AREA rockfill SAN LUIS VALLEY separation plant SLIDE ROCK BORROW specifications spillway bridge support rings talus tests trashrack structure unit valve house zone 1 material
Popular passages
Page 18 - ... PARTS 151. Character of Structure.— The structure is to be of the skeleton, curtain-beam type, resting on I-beam footings or grillages. The building is to be (18) stories high, with a basement story and a (flat) (mansard) (pointed) (hipped) roof. 152. Floor Loading.— The floors are to be calculated for a live load of (100) pounds per square foot, and a dead load of (50) pounds per square foot. The roof is to be calculated for a live load of (50) pounds per square foot, and a dead load of...
Page 22 - Specifications for Low and Intermediate Tensile Strength Carbon-Steel Plates of Flange and Firebox Qualities (Plates 2 in. and Under in Thickness) (ASTM Designation: A 285),' or Tentative Specifications for Low and Intermediate Tensile Strength Carbon-Steel Plates of Structural Quality (Plates 2 in.
Page 22 - Standard Specifications for FORGED- OR ROLLED-STEEL PIPE FLANGES, FORGED FITTINGS, AND VALVES AND PARTS FOR HIGH-TEMPERATURE SERVICE...