Platoro Dam: Constructed 1949-19511954 - Dams - 71 pages |
From inside the book
Results 1-5 of 22
Page
... abutment of dam . A high - pressure tunnel 6 feet 6 inches in diameter extends to gate chamber near axis of dam , whence a 56 - inch - diameter steel pipe extends through 8.5 - foot horseshoe tunnel to valve house . Control works : One ...
... abutment of dam . A high - pressure tunnel 6 feet 6 inches in diameter extends to gate chamber near axis of dam , whence a 56 - inch - diameter steel pipe extends through 8.5 - foot horseshoe tunnel to valve house . Control works : One ...
Page
... abutment of dam . A high - pressure tunnel 6 feet 6 inches in diameter extends to gate chamber near axis of dam , whence a 56 - inch - diameter steel pipe extends through 8.5 - foot horseshoe tunnel to valve house . Control works : One ...
... abutment of dam . A high - pressure tunnel 6 feet 6 inches in diameter extends to gate chamber near axis of dam , whence a 56 - inch - diameter steel pipe extends through 8.5 - foot horseshoe tunnel to valve house . Control works : One ...
Page v
... abutment of dike 26 38 38 The entire flow of Conejos River diverted through the outlet pipe 41 41 42 42 18. Stripping activities on the foundation of the river section of the main dam 43 19. Vicinity map showing borrow areas with test ...
... abutment of dike 26 38 38 The entire flow of Conejos River diverted through the outlet pipe 41 41 42 42 18. Stripping activities on the foundation of the river section of the main dam 43 19. Vicinity map showing borrow areas with test ...
Page vi
... abutment by means of a pumpcrete machine 29 . 30 . Structural steel used to support sections of the horseshoe portion of the outlet tunnel Placement of reinforcement steel in the high - pressure section of the outlet tunnel 31. Workmen ...
... abutment by means of a pumpcrete machine 29 . 30 . Structural steel used to support sections of the horseshoe portion of the outlet tunnel Placement of reinforcement steel in the high - pressure section of the outlet tunnel 31. Workmen ...
Page vii
... abutment . Progressing downstream , it consists of a trashrack structure , a concrete - lined high - pressure tunnel , a gate chamber , a concrete- lined horseshoe tunnel housing a 56 - inch - diameter steel pipe , and a valve house ...
... abutment . Progressing downstream , it consists of a trashrack structure , a concrete - lined high - pressure tunnel , a gate chamber , a concrete- lined horseshoe tunnel housing a 56 - inch - diameter steel pipe , and a valve house ...
Common terms and phrases
48-inch butterfly valves acre-feet andesite axis Bolt bulldozed butterfly valves cofferdam completed Concrete grout conduit Conejos River contract cost cubic feet cubic yards cutoff trench dam and dike dam embankment dam foundation dike section discharge drain emergency gate end-dump trucks engineer equipment excavation fault fault gouge feet per second Figure fill zone flange flow fractured gate chamber Government camp grout cap Grout holes haul impervious material inches installation joints July Aug Sept June 21 laboratory leaf-Class left abutment load located main dam maximum Metal metalwork mixer moisture Order for changes outlet pipe outlet tunnel PARTIAL RUNOFF percent placed placement plates Platoro Dam pounds per square pumpcrete machine right abutment Rio Grande Compact RIO GRANDE COUNTY riprap ROCK BORROW AREA rockfill SAN LUIS VALLEY separation plant SLIDE ROCK BORROW specifications spillway bridge support rings talus tests trashrack structure unit valve house zone 1 material
Popular passages
Page 18 - ... PARTS 151. Character of Structure.— The structure is to be of the skeleton, curtain-beam type, resting on I-beam footings or grillages. The building is to be (18) stories high, with a basement story and a (flat) (mansard) (pointed) (hipped) roof. 152. Floor Loading.— The floors are to be calculated for a live load of (100) pounds per square foot, and a dead load of (50) pounds per square foot. The roof is to be calculated for a live load of (50) pounds per square foot, and a dead load of...
Page 22 - Specifications for Low and Intermediate Tensile Strength Carbon-Steel Plates of Flange and Firebox Qualities (Plates 2 in. and Under in Thickness) (ASTM Designation: A 285),' or Tentative Specifications for Low and Intermediate Tensile Strength Carbon-Steel Plates of Structural Quality (Plates 2 in.
Page 22 - Standard Specifications for FORGED- OR ROLLED-STEEL PIPE FLANGES, FORGED FITTINGS, AND VALVES AND PARTS FOR HIGH-TEMPERATURE SERVICE...