Dams and Control Works, Volume 2U.S. Government Printing Office, 1938 - Dams A description of representative storage and diversion dams and high-pressure reservoir outlet works constructed by the Bureau of Reclamtion. |
From inside the book
Results 1-5 of 49
Page
PART ONE - STORAGE DAMS CONTENTS Page BOULDER DAM . Boulder Canyon Project , Arizona - California - Nevada GRAND COULEE DAM ... ARCH DAMS 235 TEMPERATURE CONTROL OF MASS CONCRETE IN LARGE DAMS DESIGN AND CONSTRUCTION OF SMALL EARTH DAMS 243 ...
PART ONE - STORAGE DAMS CONTENTS Page BOULDER DAM . Boulder Canyon Project , Arizona - California - Nevada GRAND COULEE DAM ... ARCH DAMS 235 TEMPERATURE CONTROL OF MASS CONCRETE IN LARGE DAMS DESIGN AND CONSTRUCTION OF SMALL EARTH DAMS 243 ...
Page 5
... DAM AND APPURTENANT WORKS Arizona spillway , Boulder Dam. 242 17 Concrete arch cofferdams , flanked on the river side by rock fills , were constructed at each portal to keep out water . Wooden trestles with ramps were provided over these ...
... DAM AND APPURTENANT WORKS Arizona spillway , Boulder Dam. 242 17 Concrete arch cofferdams , flanked on the river side by rock fills , were constructed at each portal to keep out water . Wooden trestles with ramps were provided over these ...
Page 7
... Dam . 茶 13 . 1 Canyon Wall Outlet Works 209'x 41'x. BOULDER DAM AND APPURTENANT WORKS Arizona spillway , Boulder Dam ... arch - gravity structure in which water load is carried by both gravity and arch ac- tion . The length along the ...
... Dam . 茶 13 . 1 Canyon Wall Outlet Works 209'x 41'x. BOULDER DAM AND APPURTENANT WORKS Arizona spillway , Boulder Dam ... arch - gravity structure in which water load is carried by both gravity and arch ac- tion . The length along the ...
Page 8
... dam and the maximum arch stresses in the horizontal elements were well below 30 tons per square foot . Resultants were at approximately the same location for both empty and full conditions of the reservoir , due to the great size of the ...
... dam and the maximum arch stresses in the horizontal elements were well below 30 tons per square foot . Resultants were at approximately the same location for both empty and full conditions of the reservoir , due to the great size of the ...
Page 15
... arch section was placed by pneumatic gun . Practically all of the concrete in the penstock tunnel lining . 2704 Plate - steel penstock 30 feet in diameter . was placed by a concrete pump . The concrete was trans- ported by cableway from ...
... arch section was placed by pneumatic gun . Practically all of the concrete in the penstock tunnel lining . 2704 Plate - steel penstock 30 feet in diameter . was placed by a concrete pump . The concrete was trans- ported by cableway from ...
Other editions - View all
Common terms and phrases
acre-feet aggregate All-American Canal arch Arrowrock Dam basin borrow pit Boulder Dam bronze BUREAU OF RECLAMATION buttress cableway canal cantilever canyon walls cement centers channel cofferdam construction contraction joints cooling cost crest cubic yards cut-off wall cylinder deflections designed diameter discharge diversion tunnel downstream face drain drainage drilled dumped earth elevation embankment emergency gates Engineering excavation feet long foundation gallery gate chamber Grand Coulee Grand Coulee Dam gravel gravity grout grout holes hoist horizontal hydraulic Imperial Dam Installing and painting irrigation left abutment located lower material maximum miles mixer needle valves operation outlet Owyhee Dam penstock pipe placed pounds per square pressure pump radial reservoir reservoir water right abutment riprap river rock fill roller sand second-feet shaft side slope sluice sluiceway spillway square inch steel storage stresses structure temperature tests thickness tion trashrack trial load upstream face vertical water surface