Trenton Dam: Constructed 1949-1953 |
From inside the book
Results 1-5 of 14
Page
... square miles Maximum flood : 200,000 second- feet ( May 31 , 1935 ) Average ... foot base width with 1-1 / 2 to 1 side slopes , length about 6 , 760 feet ... inch - diameter pipe in horseshoe conduit , 244 feet long Gates : Two , 4 by ...
... square miles Maximum flood : 200,000 second- feet ( May 31 , 1935 ) Average ... foot base width with 1-1 / 2 to 1 side slopes , length about 6 , 760 feet ... inch - diameter pipe in horseshoe conduit , 244 feet long Gates : Two , 4 by ...
Page 33
... inch round bars , spaced both ways at 12 - inch centers in the top face ... foot - wide vertical strips . The inlet walls were designed to retain the embankment of ... square foot . The walls were designed for such height that a 5 - foot ...
... inch round bars , spaced both ways at 12 - inch centers in the top face ... foot - wide vertical strips . The inlet walls were designed to retain the embankment of ... square foot . The walls were designed for such height that a 5 - foot ...
Page 34
... inch sand and gravel blanket was placed on top of the heel slab of the abut- ment walls . Drainage is collected by ... square inch , and the average web shear was limited to 12,000 pounds per square inch . The combined longitudinal and ...
... inch sand and gravel blanket was placed on top of the heel slab of the abut- ment walls . Drainage is collected by ... square inch , and the average web shear was limited to 12,000 pounds per square inch . The combined longitudinal and ...
Page 37
... foot for each operation of the push button . This provi- sion prevents inadvertent opening or closing of the gate and ... square inch . Each compressor has sufficient capacity to operate the system , but the two compressors are provided ...
... foot for each operation of the push button . This provi- sion prevents inadvertent opening or closing of the gate and ... square inch . Each compressor has sufficient capacity to operate the system , but the two compressors are provided ...
Page 39
... inch trashbars supported by 8- by 1 - inch horizontal load carrying plates , on the ends of which are attached 6- by ... square inch . 24. High - Pressure Gates . Four 6- by 7.5 - foot high - pressure gates ( fig . 17 ) are installed in ...
... inch trashbars supported by 8- by 1 - inch horizontal load carrying plates , on the ends of which are attached 6- by ... square inch . 24. High - Pressure Gates . Four 6- by 7.5 - foot high - pressure gates ( fig . 17 ) are installed in ...
Other editions - View all
Common terms and phrases
accessory cut-off trench acre-feet Approach channel Axis backfill Berm blanket Blockout BUREAU OF RECLAMATION canal outlet centerline channel capacity coarse concrete conduit construction Contraction joint Counterweight crushed rock cutoff trench dam embankment designed discharge drain outlet emergency gate chamber Expansion joint Figure Float flood control floor gate structure gravel ground surface Grouted high-pressure gate Highway bridge holes horizontal hydraulic hydrostatic head inlet installed intake structure Limits of special load located loess material maximum Metal Nebr NORTH BORROW AREA Pierre shale piezometer Pipe handrail PROJ Radial gate railroad reinforcement relocation Republican River reservoir water surface riprap River outlet Rolled embankment SCALE OF FEET second-feet SECTION A-A Settlement point Shale surface Sheet SILT silty slope special compaction spillway crest spillway gates spillway structure steel stilling basin Stoplog storage Sump Sump pump surface at elevation surfaces where directed Trashrack structure Trenton Dam upstream vertical walls water surface elevation