Trenton Dam: Constructed 1949-1953 |
From inside the book
Results 1-5 of 15
Page v
... slab 73 36 Placing concrete in a spillway pier with a crane and bucket 73 377 38 Laboratory technician preparing plastic tubing for installation of piezometer tip in the embankment Typical terminal well for 40 piezometer tips 77 78 39 ...
... slab 73 36 Placing concrete in a spillway pier with a crane and bucket 73 377 38 Laboratory technician preparing plastic tubing for installation of piezometer tip in the embankment Typical terminal well for 40 piezometer tips 77 78 39 ...
Page 17
... slab and buttress overflow crests , as was also the effect of the method of operating the gates to control the spillway discharge . The method of connecting the concrete spillway structure to the earth dam was given special ...
... slab and buttress overflow crests , as was also the effect of the method of operating the gates to control the spillway discharge . The method of connecting the concrete spillway structure to the earth dam was given special ...
Page 22
... slab and but- tress abutments . It is 90 feet in height and 438 feet in length . The overflow gravity sec- tion contains three 42- by 30 - foot steel radial gates for flood control and two 6- by 7.5- foot gated sluiceways for river ...
... slab and but- tress abutments . It is 90 feet in height and 438 feet in length . The overflow gravity sec- tion contains three 42- by 30 - foot steel radial gates for flood control and two 6- by 7.5- foot gated sluiceways for river ...
Page 23
... slab and buttress wing walls extending into the embankment on each side . The crest structure is ogee shaped with a 1 to 1 upstream slope . Discharge of the spillway is controlled by three 42 - foot - wide by 30 - foot - high radial ...
... slab and buttress wing walls extending into the embankment on each side . The crest structure is ogee shaped with a 1 to 1 upstream slope . Discharge of the spillway is controlled by three 42 - foot - wide by 30 - foot - high radial ...
Page 27
... slab and buttress design . Each inner panel has a base length of about 60 feet and a base width of about 75 feet . The outer panels are similar and are about 84 feet 6 inches long , tapering uniformly from the width of the inner panel ...
... slab and buttress design . Each inner panel has a base length of about 60 feet and a base width of about 75 feet . The outer panels are similar and are about 84 feet 6 inches long , tapering uniformly from the width of the inner panel ...
Other editions - View all
Common terms and phrases
accessory cut-off trench acre-feet Approach channel Axis backfill Berm blanket Blockout BUREAU OF RECLAMATION canal outlet centerline channel capacity coarse concrete conduit construction Contraction joint Counterweight crushed rock cutoff trench dam embankment designed discharge drain outlet emergency gate chamber Expansion joint Figure Float flood control floor gate structure gravel ground surface Grouted high-pressure gate Highway bridge holes horizontal hydraulic hydrostatic head inlet installed intake structure Limits of special load located loess material maximum Metal Nebr NORTH BORROW AREA Pierre shale piezometer Pipe handrail PROJ Radial gate railroad reinforcement relocation Republican River reservoir water surface riprap River outlet Rolled embankment SCALE OF FEET second-feet SECTION A-A Settlement point Shale surface Sheet SILT silty slope special compaction spillway crest spillway gates spillway structure steel stilling basin Stoplog storage Sump Sump pump surface at elevation surfaces where directed Trashrack structure Trenton Dam upstream vertical walls water surface elevation