Trenton Dam: Constructed 1949-1953 |
From inside the book
Results 1-5 of 21
Page i
... radial gates ( a ) Design stresses Radial gate controls ( a ) Design stresses Ice prevention system Spillway bridge River outlet trashracks High - pressure gates 27 27 32 32 32 33 33 34 34 34 34 wwwww . 37 37 37 39 39 D. Canal Outlet ...
... radial gates ( a ) Design stresses Radial gate controls ( a ) Design stresses Ice prevention system Spillway bridge River outlet trashracks High - pressure gates 27 27 32 32 32 33 33 34 34 34 34 wwwww . 37 37 37 39 39 D. Canal Outlet ...
Page iii
... Radial gates ( a ) Painting 255 75 75 75 CHAPTER VI --- TEST INSTALLATIONS 60 . Purpose 61 . Piezometer installation 62 . Settlement installations 822 77 77 APPENDIXES 83 A. Cost summary B. C. Pay item breakdown for contract 12r - 19084 ...
... Radial gates ( a ) Painting 255 75 75 75 CHAPTER VI --- TEST INSTALLATIONS 60 . Purpose 61 . Piezometer installation 62 . Settlement installations 822 77 77 APPENDIXES 83 A. Cost summary B. C. Pay item breakdown for contract 12r - 19084 ...
Page iv
... radial gate for spillway 35 15 Spillway radial gate hoist assembly 36 16 Spillway gate structure -- River outlet and gate control arrangement 38 17 Assembly and list of parts for 6- by 7-1 / 2 - foot high- pressure gate 40 18 Canal ...
... radial gate for spillway 35 15 Spillway radial gate hoist assembly 36 16 Spillway gate structure -- River outlet and gate control arrangement 38 17 Assembly and list of parts for 6- by 7-1 / 2 - foot high- pressure gate 40 18 Canal ...
Page 22
... radial gates for flood control and two 6- by 7.5- foot gated sluiceways for river control . A 266 - foot - wide channel extends from the end of the spillway stilling basin a distance of about 1 mile downstream to the river channel . An ...
... radial gates for flood control and two 6- by 7.5- foot gated sluiceways for river control . A 266 - foot - wide channel extends from the end of the spillway stilling basin a distance of about 1 mile downstream to the river channel . An ...
Page 23
... radial gates , which are arranged for automatic or manual operation depending upon the water surface elevation of the reservoir . Four 8 - foot - wide piers separate the gates and provide sup- port for a spillway bridge and gate control ...
... radial gates , which are arranged for automatic or manual operation depending upon the water surface elevation of the reservoir . Four 8 - foot - wide piers separate the gates and provide sup- port for a spillway bridge and gate control ...
Other editions - View all
Common terms and phrases
accessory cut-off trench acre-feet Approach channel Axis backfill Berm blanket Blockout BUREAU OF RECLAMATION canal outlet centerline channel capacity coarse concrete conduit construction Contraction joint Counterweight crushed rock cutoff trench dam embankment designed discharge drain outlet emergency gate chamber Expansion joint Figure Float flood control floor gate structure gravel ground surface Grouted high-pressure gate Highway bridge holes horizontal hydraulic hydrostatic head inlet installed intake structure Limits of special load located loess material maximum Metal Nebr NORTH BORROW AREA Pierre shale piezometer Pipe handrail PROJ Radial gate railroad reinforcement relocation Republican River reservoir water surface riprap River outlet Rolled embankment SCALE OF FEET second-feet SECTION A-A Settlement point Shale surface Sheet SILT silty slope special compaction spillway crest spillway gates spillway structure steel stilling basin Stoplog storage Sump Sump pump surface at elevation surfaces where directed Trashrack structure Trenton Dam upstream vertical walls water surface elevation