... Gates : Two , 4 by 4 feet ( one is in- stalled in the emergency gate chamber and the other in the control house ) Discharge capacity : 300 second - feet with reservoir water surface eleva- tion 2720.0 , and canal water elevation 2705.0 ...
... Gates : Two , 4 by 4 feet ( one is in- stalled in the emergency gate chamber and the other in the control house ) Discharge capacity : 300 second - feet with reservoir water surface eleva- tion 2720.0 , and canal water elevation 2705.0 ...
Page ii
... Emergency gate chamber Horseshoe conduit ( a ) Loadings ( b ) Design considerations Outlet pipe Control house and stilling well ( a ) Design considerations High - pressure gates Miscellaneous equipment E. Railroad Structures Page 41 41 ...
... Emergency gate chamber Horseshoe conduit ( a ) Loadings ( b ) Design considerations Outlet pipe Control house and stilling well ( a ) Design considerations High - pressure gates Miscellaneous equipment E. Railroad Structures Page 41 41 ...
Page 22
... emergency gate chamber located near the axis of the dam . A horse- shoe conduit , about 244 feet long and containing a 56 - inch steel outlet pipe , extends from the emergency gate chamber to a control house and stilling well structure ...
... emergency gate chamber located near the axis of the dam . A horse- shoe conduit , about 244 feet long and containing a 56 - inch steel outlet pipe , extends from the emergency gate chamber to a control house and stilling well structure ...
Page 37
... gate structure ( fig . 16 ) . An emergency intake will admit water to the ... chamber , sand , and asphalt to make its weight about 10 percent more than ... gate , and connected to the hoist drums with gears , shafts , and an over- riding ...
... gate structure ( fig . 16 ) . An emergency intake will admit water to the ... chamber , sand , and asphalt to make its weight about 10 percent more than ... gate , and connected to the hoist drums with gears , shafts , and an over- riding ...
Page 41
... emergency gate chamber , station 4 + 68 , and was constructed in sections each of which is provided with a cutoff collar . The gate chamber houses a 4- by 4 - foot high - pressure , hydraulically operated emergency slide gate . An 8 ...
... emergency gate chamber , station 4 + 68 , and was constructed in sections each of which is provided with a cutoff collar . The gate chamber houses a 4- by 4 - foot high - pressure , hydraulically operated emergency slide gate . An 8 ...
Other editions - View all
Common terms and phrases
accessory cut-off trench acre-feet Approach channel Axis backfill Berm blanket Blockout BUREAU OF RECLAMATION canal outlet centerline channel capacity coarse concrete conduit construction Contraction joint Counterweight crushed rock cutoff trench dam embankment designed discharge drain outlet emergency gate chamber Expansion joint Figure Float flood control floor gate structure gravel ground surface Grouted high-pressure gate Highway bridge holes horizontal hydraulic hydrostatic head inlet installed intake structure Limits of special load located loess material maximum Metal Nebr NORTH BORROW AREA Pierre shale piezometer Pipe handrail PROJ Radial gate railroad reinforcement relocation Republican River reservoir water surface riprap River outlet Rolled embankment SCALE OF FEET second-feet SECTION A-A Settlement point Shale surface Sheet SILT silty slope special compaction spillway crest spillway gates spillway structure steel stilling basin Stoplog storage Sump Sump pump surface at elevation surfaces where directed Trashrack structure Trenton Dam upstream vertical walls water surface elevation