Trenton Dam: Constructed 1949-1953 |
From inside the book
Results 1-5 of 25
Page
... discharge : 126 , 500 second- feet at water surface elevation 2785.6 ( as determined by model studies ) Gates : Three , 42 by 30 feet Stilling basin : Reinforced concrete with dentated sills River Outlets Outlets : Two Invert ...
... discharge : 126 , 500 second- feet at water surface elevation 2785.6 ( as determined by model studies ) Gates : Three , 42 by 30 feet Stilling basin : Reinforced concrete with dentated sills River Outlets Outlets : Two Invert ...
Page iv
... discharge curves 44 20 Pressure conduit of canal outlet works -- Compacting backfill around conduit 45 21 Canal outlet works -- Gate chambers and stilling well details 46 22 2 23 22 Control house and stilling well for canal outlet works ...
... discharge curves 44 20 Pressure conduit of canal outlet works -- Compacting backfill around conduit 45 21 Canal outlet works -- Gate chambers and stilling well details 46 22 2 23 22 Control house and stilling well for canal outlet works ...
Page 1
... discharge capacity of 126 , 500 second- feet , constructed through the left abutment , protects the structure from possible flood damage . A river outlet is provided through the spillway structure for river regulation . At the opposite ...
... discharge capacity of 126 , 500 second- feet , constructed through the left abutment , protects the structure from possible flood damage . A river outlet is provided through the spillway structure for river regulation . At the opposite ...
Page 15
... Discharge capacities of regulating structures were speci- fied and allocations in the reservoir were made as follows : Purpose Flood control Water surface elevation 2752.0 to 2773.0 Storage , acre - feet Irrigation storage Dead storage ...
... Discharge capacities of regulating structures were speci- fied and allocations in the reservoir were made as follows : Purpose Flood control Water surface elevation 2752.0 to 2773.0 Storage , acre - feet Irrigation storage Dead storage ...
Page 16
... DISCHARGE IN THOUSANDS OF C. F. S. 80 00 40 Royal adW WORSED hate a ZA 120 180 2752 2756 2760 2764 Letter dated 5-17 ... DISCHARGE 129,500 C.F.S. NOTES The discharge - elevation curve is based on automatic hydraulic operation for ...
... DISCHARGE IN THOUSANDS OF C. F. S. 80 00 40 Royal adW WORSED hate a ZA 120 180 2752 2756 2760 2764 Letter dated 5-17 ... DISCHARGE 129,500 C.F.S. NOTES The discharge - elevation curve is based on automatic hydraulic operation for ...
Other editions - View all
Common terms and phrases
accessory cut-off trench acre-feet Approach channel Axis backfill Berm blanket Blockout BUREAU OF RECLAMATION canal outlet centerline channel capacity coarse concrete conduit construction Contraction joint Counterweight crushed rock cutoff trench dam embankment designed discharge drain outlet emergency gate chamber Expansion joint Figure Float flood control floor gate structure gravel ground surface Grouted high-pressure gate Highway bridge holes horizontal hydraulic hydrostatic head inlet installed intake structure Limits of special load located loess material maximum Metal Nebr NORTH BORROW AREA Pierre shale piezometer Pipe handrail PROJ Radial gate railroad reinforcement relocation Republican River reservoir water surface riprap River outlet Rolled embankment SCALE OF FEET second-feet SECTION A-A Settlement point Shale surface Sheet SILT silty slope special compaction spillway crest spillway gates spillway structure steel stilling basin Stoplog storage Sump Sump pump surface at elevation surfaces where directed Trashrack structure Trenton Dam upstream vertical walls water surface elevation