Trenton Dam: Constructed 1949-1953 |
From inside the book
Results 1-5 of 14
Page
... chute type with stilling basin Crest length of overflow section : 126 feet Crest : Elevation 2743.00 Maximum discharge : 126 , 500 second- feet at water surface elevation 2785.6 ( as determined by model studies ) Gates : Three , 42 by ...
... chute type with stilling basin Crest length of overflow section : 126 feet Crest : Elevation 2743.00 Maximum discharge : 126 , 500 second- feet at water surface elevation 2785.6 ( as determined by model studies ) Gates : Three , 42 by ...
Page i
... Chute and stilling basin 19 . 20 . 21 . 22 . 23 . 24 . ( a ) Floors ( b ) Walls ( c ) Drains 42- by 30 - foot radial gates ( a ) Design stresses Radial gate controls ( a ) Design stresses Ice prevention system Spillway bridge River ...
... Chute and stilling basin 19 . 20 . 21 . 22 . 23 . 24 . ( a ) Floors ( b ) Walls ( c ) Drains 42- by 30 - foot radial gates ( a ) Design stresses Radial gate controls ( a ) Design stresses Ice prevention system Spillway bridge River ...
Page 23
... chute . Each outlet has an invert elevation of 2710.00 and is provided with two 6- by 7.5 - foot high - pressure gates installed in tandem . The upstream gate is for emergency use only , and the downstream gate is for regulating the ...
... chute . Each outlet has an invert elevation of 2710.00 and is provided with two 6- by 7.5 - foot high - pressure gates installed in tandem . The upstream gate is for emergency use only , and the downstream gate is for regulating the ...
Page 30
... chute wall Formed drain Sta30 2300 Sta . 30.80.97 . --Vent line with grout outets at 6'crs . horizontally Type 2 metal sealing strip S0.010 EL 2710.00- with cemented joints EL 2734.00 S = 0.065 12 " Drain outlet Trashrack structure-- 24 ...
... chute wall Formed drain Sta30 2300 Sta . 30.80.97 . --Vent line with grout outets at 6'crs . horizontally Type 2 metal sealing strip S0.010 EL 2710.00- with cemented joints EL 2734.00 S = 0.065 12 " Drain outlet Trashrack structure-- 24 ...
Page 31
... Chute floor slab . El 2690 ( 5-0 Av 4-9 " Min SECTIONAL ELEVATION B - B Top of curb Protective fence El . 2793.75 at supports Structural steel cover Structural steel cover Crown E1.279317 at supports 12 -Type Z metal sealing strip ...
... Chute floor slab . El 2690 ( 5-0 Av 4-9 " Min SECTIONAL ELEVATION B - B Top of curb Protective fence El . 2793.75 at supports Structural steel cover Structural steel cover Crown E1.279317 at supports 12 -Type Z metal sealing strip ...
Other editions - View all
Common terms and phrases
accessory cut-off trench acre-feet Approach channel Axis backfill Berm blanket Blockout BUREAU OF RECLAMATION canal outlet centerline channel capacity coarse concrete conduit construction Contraction joint Counterweight crushed rock cutoff trench dam embankment designed discharge drain outlet emergency gate chamber Expansion joint Figure Float flood control floor gate structure gravel ground surface Grouted high-pressure gate Highway bridge holes horizontal hydraulic hydrostatic head inlet installed intake structure Limits of special load located loess material maximum Metal Nebr NORTH BORROW AREA Pierre shale piezometer Pipe handrail PROJ Radial gate railroad reinforcement relocation Republican River reservoir water surface riprap River outlet Rolled embankment SCALE OF FEET second-feet SECTION A-A Settlement point Shale surface Sheet SILT silty slope special compaction spillway crest spillway gates spillway structure steel stilling basin Stoplog storage Sump Sump pump surface at elevation surfaces where directed Trashrack structure Trenton Dam upstream vertical walls water surface elevation