Trenton Dam: Constructed 1949-1953 |
From inside the book
Results 1-5 of 19
Page iii
... Cement 5565 66 C. Concrete 66 66 66 67 67 69 69 71 71 74 74 74 51 . Reinforcement steel 52 . Forms 53 . 54 . 55 . 56 . 57 . Batching and mixing Control Placement ( a ) Cold weather operations Curing Contraction joint grouting D. Gate ...
... Cement 5565 66 C. Concrete 66 66 66 67 67 69 69 71 71 74 74 74 51 . Reinforcement steel 52 . Forms 53 . 54 . 55 . 56 . 57 . Batching and mixing Control Placement ( a ) Cold weather operations Curing Contraction joint grouting D. Gate ...
Page 42
... Cement grout or comparable El 2760 Intake structure Sta 2 + 50.00 ---- Sta . 2 + 40.5- . Min . operating WS . EL 2720.0- El 2706.0- EL 2710.00 -Sta 2 + 840 EL 2720.5 Sto , 2.65.00 --Approximate surface of accessory cut - off trench ...
... Cement grout or comparable El 2760 Intake structure Sta 2 + 50.00 ---- Sta . 2 + 40.5- . Min . operating WS . EL 2720.0- El 2706.0- EL 2710.00 -Sta 2 + 840 EL 2720.5 Sto , 2.65.00 --Approximate surface of accessory cut - off trench ...
Page 43
... cement- Cut - off collar 50Av Preformed joint filler- Bottom of excavation of accessory cutoff trench 8- 6,3 75 . -8-8- Drain hole -Pipe support Shale surface Bottom of excavation of accessory cut - off trench Limits of canal outlet ...
... cement- Cut - off collar 50Av Preformed joint filler- Bottom of excavation of accessory cutoff trench 8- 6,3 75 . -8-8- Drain hole -Pipe support Shale surface Bottom of excavation of accessory cut - off trench Limits of canal outlet ...
Page 46
... cement valve 4 " Gutter EEL 2680.10 56 10 Pipe E12679.67 El 2679.00 26 . EL2673.75 8 " Gate by - pass- 4 " Floor drain Shale surface --- Inv . El 2671 00 Sta 4 + 65.63 Expansion joint cement-- EL 2671,42 24 Av 21 Min -Sta 4 + 68.00 ...
... cement valve 4 " Gutter EEL 2680.10 56 10 Pipe E12679.67 El 2679.00 26 . EL2673.75 8 " Gate by - pass- 4 " Floor drain Shale surface --- Inv . El 2671 00 Sta 4 + 65.63 Expansion joint cement-- EL 2671,42 24 Av 21 Min -Sta 4 + 68.00 ...
Page 57
... cement for 3148 structures , relo- Ideal Cement Co. , Denver , Colo . 58,000 cation of Chicago , Burlington and Quincy Railroad around Trenton Dam - 39. Housing . A housing project for Bureau personnel was located close to the east edge ...
... cement for 3148 structures , relo- Ideal Cement Co. , Denver , Colo . 58,000 cation of Chicago , Burlington and Quincy Railroad around Trenton Dam - 39. Housing . A housing project for Bureau personnel was located close to the east edge ...
Other editions - View all
Common terms and phrases
accessory cut-off trench acre-feet Approach channel Axis backfill Berm blanket Blockout BUREAU OF RECLAMATION canal outlet centerline channel capacity coarse concrete conduit construction Contraction joint Counterweight crushed rock cutoff trench dam embankment designed discharge drain outlet emergency gate chamber Expansion joint Figure Float flood control floor gate structure gravel ground surface Grouted high-pressure gate Highway bridge holes horizontal hydraulic hydrostatic head inlet installed intake structure Limits of special load located loess material maximum Metal Nebr NORTH BORROW AREA Pierre shale piezometer Pipe handrail PROJ Radial gate railroad reinforcement relocation Republican River reservoir water surface riprap River outlet Rolled embankment SCALE OF FEET second-feet SECTION A-A Settlement point Shale surface Sheet SILT silty slope special compaction spillway crest spillway gates spillway structure steel stilling basin Stoplog storage Sump Sump pump surface at elevation surfaces where directed Trashrack structure Trenton Dam upstream vertical walls water surface elevation