Trenton Dam: Constructed 1949-1953 |
From inside the book
Results 1-5 of 18
Page 23
... installed in tandem . The upstream gate is for emergency use only , and the downstream gate is for regulating the flow through the outlet . The river outlets are an integral part of the spillway and are designed to discharge 1,000 ...
... installed in tandem . The upstream gate is for emergency use only , and the downstream gate is for regulating the flow through the outlet . The river outlets are an integral part of the spillway and are designed to discharge 1,000 ...
Page 39
... installed side by side in the structure . For maintaining uniform alinement , each inclined section is provided with dowels which engage into the adjacent section . These sections consist of 2- by 5 / 8 - inch trashbars supported by 8 ...
... installed side by side in the structure . For maintaining uniform alinement , each inclined section is provided with dowels which engage into the adjacent section . These sections consist of 2- by 5 / 8 - inch trashbars supported by 8 ...
Page 51
... installed in the canal outlet works , one in an emergency gate chamber and the other in a regulating gate chamber in the gate control house . The gate in the emergency gate chamber is for emergency use only and is provided with a ...
... installed in the canal outlet works , one in an emergency gate chamber and the other in a regulating gate chamber in the gate control house . The gate in the emergency gate chamber is for emergency use only and is provided with a ...
Page 57
... installed under contract by Jansen and Ells Con- struction Co. , Beatrice , Nebr . , who submitted the low bid of $ 24 , 807. The work in- volved furnishing and installing about 8,000 feet of sewer pipe , 3,000 feet of water pipe , and ...
... installed under contract by Jansen and Ells Con- struction Co. , Beatrice , Nebr . , who submitted the low bid of $ 24 , 807. The work in- volved furnishing and installing about 8,000 feet of sewer pipe , 3,000 feet of water pipe , and ...
Page 60
... installed on the side slopes for dewatering the area . A. Excavation 44. Foundation Area . The entire area to. Figure 25 .-- Stripping dam foundation area . Material suitable for later use was stockpiles . P404-1266C , August 1 , 1949 ...
... installed on the side slopes for dewatering the area . A. Excavation 44. Foundation Area . The entire area to. Figure 25 .-- Stripping dam foundation area . Material suitable for later use was stockpiles . P404-1266C , August 1 , 1949 ...
Other editions - View all
Common terms and phrases
abutment acre-feet aggregate backfill Berm blanket blockouts Brass Cap BUREAU OF RECLAMATION camber canal outlet cement centerline chute coarse concrete construction Contraction joint contractor control house crushed rock cubic yards cutoff trench dam embankment dam foundation designed discharge eleva emergency gate chamber Figure Float flood control gravel grout high-pressure gates Highway bridge Hitchcock County holes horizontal hydraulic hydrostatic head inlet intake structure layer Limits of special loads located loess material maximum metal Nebr north borrow operation pier Pierre shale piezometer Pipe handrail pounds per square pozzolan PROJ pump radial gate railroad reinforcement relocation Republican River reservoir water surface riprap River outlet Rolled embankment SCALE OF FEET second-feet Settlement point Shale surface SILT silty slope south borrow area special compaction specifications spillway structure steel stilling basin storage Sump Sump pump surface at elevation tests Trenton Dam upstream valve vertical walls water surface elevation
Popular passages
Page 51 - Design, Construction, Inspection and Repair of Unfired Pressure Vessels for Petroleum Liquids and Gases.
Page 99 - yd. cu. yd. lin. ft. lin. ft. lin. ft. Labor and materials by contractor Unit cost
Page 94 - yd. cu. yd. cu. yd. cu. yd. Labor and materials by contractor Unit cost
Page 96 - ft. lin. ft. lin. ft. lin. ft. Labor and materials by contractor Unit cost
Page 100 - cu. yd. Lump sum Lump sum Labor and materials by contractor Unit cost 2.00
Page 99 - 88 89 90 91 92 93 94 Property and pay item description Installing metal pipe, fittings, and valves less than 6 inches in diameter Installing metal pipe, fittings, and valves 6 inches
Page 25 - above the maximum water surface, to prevent the dam from being overtopped by waves. Factors influencing wave height and wave ride-up, including maximum wind velocity, direction and duration, offshore reservoir
Page 98 - ft. Ib. Ib. Ib. Ib. Ib. Ib. Ib. Labor and materials by contractor Unit cost