Trenton Dam: Constructed 1949-1953 |
From inside the book
Results 1-5 of 16
Page
... emergency gate chamber and the other in the control house ) Discharge capacity : 300 second - feet with reservoir water surface eleva- tion 2720.0 , and canal water elevation 2705.0 20.58 AERIAL VIEW OF TRENTON DAM SPILLWAY DURING ...
... emergency gate chamber and the other in the control house ) Discharge capacity : 300 second - feet with reservoir water surface eleva- tion 2720.0 , and canal water elevation 2705.0 20.58 AERIAL VIEW OF TRENTON DAM SPILLWAY DURING ...
Page ii
... Emergency gate chamber Horseshoe conduit ( a ) Loadings ( b ) Design considerations Outlet pipe Control house and stilling well ( a ) Design considerations High - pressure gates Miscellaneous equipment E. Railroad Structures Page 41 41 ...
... Emergency gate chamber Horseshoe conduit ( a ) Loadings ( b ) Design considerations Outlet pipe Control house and stilling well ( a ) Design considerations High - pressure gates Miscellaneous equipment E. Railroad Structures Page 41 41 ...
Page 22
... emergency gate chamber located near the axis of the dam . A horse- shoe conduit , about 244 feet long and containing a 56 - inch steel outlet pipe , extends from the emergency gate chamber to a control house and stilling well structure ...
... emergency gate chamber located near the axis of the dam . A horse- shoe conduit , about 244 feet long and containing a 56 - inch steel outlet pipe , extends from the emergency gate chamber to a control house and stilling well structure ...
Page 23
... emergency use only , and the downstream gate is for regulating the flow through the outlet . The river outlets are an integral part of the spillway and are designed to discharge 1,000 second - feet with reservoir water surface at ...
... emergency use only , and the downstream gate is for regulating the flow through the outlet . The river outlets are an integral part of the spillway and are designed to discharge 1,000 second - feet with reservoir water surface at ...
Page 34
... emergency flood stage , the gate will be automatically raised by the float system without the use of the motor - driven hoists . End guide shoes at each gate control lateral movement of the gate . A 28 - inch- diameter manhole located ...
... emergency flood stage , the gate will be automatically raised by the float system without the use of the motor - driven hoists . End guide shoes at each gate control lateral movement of the gate . A 28 - inch- diameter manhole located ...
Other editions - View all
Common terms and phrases
abutment acre-feet aggregate backfill Berm blanket blockouts Brass Cap BUREAU OF RECLAMATION camber canal outlet cement centerline chute coarse concrete construction Contraction joint contractor control house crushed rock cubic yards cutoff trench dam embankment dam foundation designed discharge eleva emergency gate chamber Figure Float flood control gravel grout high-pressure gates Highway bridge Hitchcock County holes horizontal hydraulic hydrostatic head inlet intake structure layer Limits of special loads located loess material maximum metal Nebr north borrow operation pier Pierre shale piezometer Pipe handrail pounds per square pozzolan PROJ pump radial gate railroad reinforcement relocation Republican River reservoir water surface riprap River outlet Rolled embankment SCALE OF FEET second-feet Settlement point Shale surface SILT silty slope south borrow area special compaction specifications spillway structure steel stilling basin storage Sump Sump pump surface at elevation tests Trenton Dam upstream valve vertical walls water surface elevation
Popular passages
Page 51 - Design, Construction, Inspection and Repair of Unfired Pressure Vessels for Petroleum Liquids and Gases.
Page 99 - yd. cu. yd. lin. ft. lin. ft. lin. ft. Labor and materials by contractor Unit cost
Page 94 - yd. cu. yd. cu. yd. cu. yd. Labor and materials by contractor Unit cost
Page 96 - ft. lin. ft. lin. ft. lin. ft. Labor and materials by contractor Unit cost
Page 100 - cu. yd. Lump sum Lump sum Labor and materials by contractor Unit cost 2.00
Page 99 - 88 89 90 91 92 93 94 Property and pay item description Installing metal pipe, fittings, and valves less than 6 inches in diameter Installing metal pipe, fittings, and valves 6 inches
Page 25 - above the maximum water surface, to prevent the dam from being overtopped by waves. Factors influencing wave height and wave ride-up, including maximum wind velocity, direction and duration, offshore reservoir
Page 98 - ft. Ib. Ib. Ib. Ib. Ib. Ib. Ib. Labor and materials by contractor Unit cost