APPENDIX F

Design criteria:

The stability factors and loadings used in the design of the spillway and outlet works were as follows:

Allowable sliding factor = . 30 Spillway gate structure (maximum)

= .35 Spillway inlet walls

= .40 Spillway chute walls and
abutment walls

= . 45 Spillway stilling basin walls

= . 50 Abutment walls (no downstream
earth loads)

[blocks in formation]

Weight of dry earth fill 120 lb. per cu. ft.

130 (for conduits, spillway inlet walls)

[blocks in formation]

Design of all concrete structures was based on concrete of 3,000 pounds per square inch compressive strength at 28 days and a modular ratio of 10. Allowable working stresses in pounds per square inch for all concrete structures except pressure and horseshoe conduits, for which other steel tension and concrete compressive stresses were used under certain loading conditions, are indicated below:

[ocr errors][merged small][ocr errors]

Allowable steel tension and concrete compressive stresses in pounds per square inch for conduits are as follows:

APPENDIX F (Continued)

Normal loading f f c s

External loads 1,350 20,000

Internal load combined with 18,000 - 40h

external loads 2j 1,350 (h = head in

feet on centerline of conduit)

Extraordinary loading (investigated only)

Internal load combined with vertical

loads and no lateral loads 2/ 3,000 40,000

Vertical loads and no lateral

loads 3/ 3,000 40,000

2/ Pressure conduit only
7/ Horseshoe conduit only