Gas Analyst's Manual |
From inside the book
Results 1-5 of 93
Page
... SULPHUR AND AMMONIA IN GAS 175 VI COAL TESTING 202 VII TESTING ENRICHMENT AND PURIFICATION MATE- RIALS · 223 XI VIII PURITY TESTS FOR GAS IN VARIOUS STAGES OF MANUFACTURE IX TESTING BYE - PRODUCTS X TECHNICAL GAS ANALYSIS METER ...
... SULPHUR AND AMMONIA IN GAS 175 VI COAL TESTING 202 VII TESTING ENRICHMENT AND PURIFICATION MATE- RIALS · 223 XI VIII PURITY TESTS FOR GAS IN VARIOUS STAGES OF MANUFACTURE IX TESTING BYE - PRODUCTS X TECHNICAL GAS ANALYSIS METER ...
Page 8
... sulphur- etted hydrogen . - A glass vessel containing a strip of bibulous paper moistened with a solution of acetate of lead , containing sixty grains of crystal- lized acetate of lead dissolved in one fluid ounce of water . PART II ...
... sulphur- etted hydrogen . - A glass vessel containing a strip of bibulous paper moistened with a solution of acetate of lead , containing sixty grains of crystal- lized acetate of lead dissolved in one fluid ounce of water . PART II ...
Page 26
... Sulphur Compounds " other than sulphuretted hydrogen . " The time for exposure of the test papers is , under the Gas Works Clauses Amendment Act , three minutes , or such time as may be fixed [ par . 15 ( a ) , Part II . ] , but in ...
... Sulphur Compounds " other than sulphuretted hydrogen . " The time for exposure of the test papers is , under the Gas Works Clauses Amendment Act , three minutes , or such time as may be fixed [ par . 15 ( a ) , Part II . ] , but in ...
Page 167
... . This is calibrated by weighing air in the globe at 15 ° Centigrade and 760 millimetres ' pressure , and marking the indicated. FIG . 40a . - LUX SPECIFIC GRAVITY BALANCE . FIG . 41. - REFEREES ' SULPHUR TEST . CALORIMETRY . 167.
... . This is calibrated by weighing air in the globe at 15 ° Centigrade and 760 millimetres ' pressure , and marking the indicated. FIG . 40a . - LUX SPECIFIC GRAVITY BALANCE . FIG . 41. - REFEREES ' SULPHUR TEST . CALORIMETRY . 167.
Page 175
... sulphur , " other than sulphuretted hydrogen , ” which 100 cubic feet of the gas contains . Time and Mode of Testing for Purity in London . 301. The testings for purity shall extend over not less than fifteen hours of each day , and ...
... sulphur , " other than sulphuretted hydrogen , ” which 100 cubic feet of the gas contains . Time and Mode of Testing for Purity in London . 301. The testings for purity shall extend over not less than fifteen hours of each day , and ...
Other editions - View all
Common terms and phrases
100 cubic feet absorbed absorption adjusted ammonia Amount Reading apparatus Argand burner ascertained barium barometer bottle burette burning calculated calorific power calorimeter candles capillary tube carbonic acid cent chloride CO₂ coal cock colour combustion connected consumption containing correct crown 8vo cubic centimetres cubic foot demy 8vo disc distilled water Engineers Fahr fcap flame flask fuel gallon Gas Holder Gas Referees gases gasholder gauge glass grains grammes H₂S heat Holder of Error hour hydrochloric acid hydrogen illuminating power illus inches inlet lamp light liquid liquor measured mercury meter method millimetres minutes naphthalene observed ounces outlet oxide oxygen passed Pentane Photometer Photoped picric acid pipe pipette placed plates pointer pressure quantity Reading of Amount residue sample Scale of Gas Second edition septems solution specific gravity sperm Spermaceti stopper sulphate sulphur TABLE Tabular Number temperature test-meter thermometer tion vapour water gas weight York ΙΟ
Popular passages
Page 14 - Key to the Theory and Methods of Linear Perspective. By CW DYMOND, FSA 6 plates, 32 pp. crown 8vo, limp.
Page 400 - ... in any such action by leave of the court where such action shall depend at any time before issue joined to pay into court such sum of money as he shall...
Page 400 - ... if a verdict shall pass for the defendant, or the plaintiff shall become nonsuit, or discontinue...
Page 20 - York, 1902.) 4s. 6d. net. Wiring Rules. With Extracts from the Board of Trade Regulations and the Home Office Regulations for Factories and Workshops. Issued by The Institution of Electrical Engineers. Sixth edition, 42 pp., 8vo, sewed. (1911.) 6d.
Page 235 - The air chamber which surrounds the cup is filled with cold water to a depth of 14 inch, and the heating vessel or water bath is filled as usual, but also with cold water. The lamp is then placed under the apparatus, and kept there during the entire operation. If a very heavy oil is being dealt with. the operation may be commenced with water previously heated to 120°, instead of with cold water.
Page 5 - Our Factories, Workshops, and Warehouses : their Sanitary and Fire-Resisting Arrangements. By BH THWAITE, Assoc. Mem. Inst. CE With 183 wood engravings, crown 8vo, cloth, gs.
Page 12 - The Drainage of Fens and Low Lands by .Gravitation and Steam Power. By WH WHEELER. 8 plates, 175 pp. 8vo. (1888) ... 12 6 Stadia Surveying, the theory of Stadia Measurements.
Page 399 - ... or if- upon demurrer judgment shall be given against the plaintiff or plaintiffs, the defendant or defendants...
Page 399 - ... and in any such action the defendant may plead the general issue, and give this Act and the special matter in evidence at any trial to be had thereupon...
Page 6 - Alexander. 101 illus., xii + 265 pp., demy 8vo., (1912.) los. 6d. net. A Practical Treatise on Segmental and Elliptical Oblique or Skew Arches. By GJ Bell. Second edition, 17 plates, 125 pp., royal 8vo. (1906.) £1 1s.