Power Transformers: Principles and ApplicationsComplete with equations, illustrations, and tables, this book covers the basic theory of electric power transformers, its application to transformer designs, and their application in utility and industrial power systems. The author presents the principles of the two-winding transformer and its connection to polyphase systems, the origins of transformer losses, autotransformers, and three-winding transformers and compares different types of transformer coil and coil construction. He describes the effects of short circuits on transformers, the design and maintenance of ancillary equipment, and preventative and predictive maintenance practices for extending transformer life. |
From inside the book
Results 1-5 of 21
Page 4
... normal component of the magnetic field intensity B over any surface within the closed path : where = B. dA ( 1.4.1 ) dA = = flux , Wb incremental surface area , m2 If the total flux is changing over time , there is an induced voltage E ...
... normal component of the magnetic field intensity B over any surface within the closed path : where = B. dA ( 1.4.1 ) dA = = flux , Wb incremental surface area , m2 If the total flux is changing over time , there is an induced voltage E ...
Page 29
You have reached your viewing limit for this book.
You have reached your viewing limit for this book.
Page 32
You have reached your viewing limit for this book.
You have reached your viewing limit for this book.
Page 58
You have reached your viewing limit for this book.
You have reached your viewing limit for this book.
Page 60
You have reached your viewing limit for this book.
You have reached your viewing limit for this book.
Contents
1 | |
2 TwoWinding Transformer Connections | 25 |
3 Transformer Impedance and Losses | 69 |
4 Autotransformers and ThreeWinding Transformers | 117 |
5 Short Circuits Inrush Currents and Other Phenomena | 147 |
6 Ancillary Equipment | 189 |
7 Reading and Applying Nameplate Information | 221 |
8 Maintenance Testing Troubleshooting and Reliability | 235 |
Index | 277 |
Other editions - View all
Common terms and phrases
A-connected ampere ampere-turns autotransformer B-H curve bushings calculated clip test common winding conductor cooling class copper losses core and coil core form transformer core leg core losses electrical equal equivalent circuit Example exciting current fault current Filtered oil flux density forces harmonic high-voltage IEEE induced voltages insulation kraft paper KVA base KVA rating load current load tap changer magnetic flux magnetizing current nameplate neutral oil level operating output path phase angle phase rotation phase sequence networks phase-to-ground fault phase-to-neutral phase-to-phase power transformers primary and secondary primary voltage primary winding secondary voltage secondary windings sequence currents series impedance series winding shown in Figure single-phase transformers symmetrical components tap changer terminals tertiary winding test report three-phase three-winding transformer trans transformer connection transformer impedance transformer tank turns ratio two-winding transformer unit vector diagram volt voltage rating voltage surge winding temperature Y-Y connection zero phase sequence zero-sequence