Code of Federal RegulationsU.S. General Services Administration, National Archives and Records Service, Office of the Federal Register, 2005 - Administrative law |
From inside the book
Results 1-5 of 73
Page 10
... indicating silica gel as shown in Figure 2. Glass wool may be sub- stituted for silica gel when collecting short- term samples ( 1 hour or less ) as shown in Figure 1 , or for long term ( 24 hour ) samples if flow changes are not ...
... indicating silica gel as shown in Figure 2. Glass wool may be sub- stituted for silica gel when collecting short- term samples ( 1 hour or less ) as shown in Figure 1 , or for long term ( 24 hour ) samples if flow changes are not ...
Page 14
... indicating paper or a pH meter . If the pH of the solution is not between 3.0 and 5.0 , dispose of the solution according to one of the disposal techniques described in Section 13.0 . The absorbing reagent is nor- mally stable for 6 ...
... indicating paper or a pH meter . If the pH of the solution is not between 3.0 and 5.0 , dispose of the solution according to one of the disposal techniques described in Section 13.0 . The absorbing reagent is nor- mally stable for 6 ...
Page 18
... indicated by the flowmeter in the sam- pling train ( Qc ) by more than 5 percent as de- termined by equation ( 8 ) ... indicated volumes of the sulfite - TCM solutions into a series of 25 - mL volumetric flasks . Add TCM absorbing reagent ...
... indicated by the flowmeter in the sam- pling train ( Qc ) by more than 5 percent as de- termined by equation ( 8 ) ... indicated volumes of the sulfite - TCM solutions into a series of 25 - mL volumetric flasks . Add TCM absorbing reagent ...
Page 27
... indicate the approxi- mate air temperature at the flow rate meas- urement orifice , when temperature correc- tions are used . 7.5.1 Range : -40 ° to +50 ° C ( 223–323 K ) . 7.5.2 Resolution : 2 ° C ( 2 K ) . 7.6 Barometer , to indicate ...
... indicate the approxi- mate air temperature at the flow rate meas- urement orifice , when temperature correc- tions are used . 7.5.1 Range : -40 ° to +50 ° C ( 223–323 K ) . 7.5.2 Resolution : 2 ° C ( 2 K ) . 7.6 Barometer , to indicate ...
Page 28
... indicating or control device is necessary to establish traceability of the field measurement to a primary standard via a flow rate transfer standard . Figure 3a illus- trates the certification of the flow rate transfer standard and ...
... indicating or control device is necessary to establish traceability of the field measurement to a primary standard via a flow rate transfer standard . Figure 3a illus- trates the certification of the flow rate transfer standard and ...
Other editions - View all
Common terms and phrases
actual emissions adjustment air pollution air quality air quality standards ambient air quality amount appendix applicable approved arithmetic mean average calculated calibration chapter Clean Air Act Clean Unit designation cogeneration compliance comply concentration control measures control technology determined device emis emission factor emission limitation emissions data emissions increase emissions reductions emissions trading emissions trading program emissions unit enforceable Federal filter flow rate fuel graph implementation plan inventory major modification major stationary source maximum ments monitoring nitrogen dioxide NO₂ non-EGUS nonattainment nonroad NOx Budget NOx emissions number of exceedances owner or operator ozone season PAL permit PAL pollutant particulate matter percent PLCS procedures pursuant quirements reporting requirements of paragraph reviewing authority sample period sampler sions unit SIP revision specified stack State's submit subpart sulfur dioxide temperature throughput tion tons unit's vehicle volumetric flask µg/m³