... adjustment of concentration ( Section 8.2.12.4 ) and prepare a reagent blank ( Section 11.2 ) ; the absorbance of this reagent blank at 540 nm should be less than 0.170 at 22 ° C . If the absorbance is greater than 0.170 under these ...
... adjustment of concentration ( Section 8.2.12.4 ) and prepare a reagent blank ( Section 11.2 ) ; the absorbance of this reagent blank at 540 nm should be less than 0.170 at 22 ° C . If the absorbance is greater than 0.170 under these ...
Page 19
... adjusting the dilu- tion flow rates appropriately . The concentra- tion of SO2 in each atmosphere is calculated as follows : where : P , × 103 r C = ( 12 ) Qd + Qp NEEDLE VALVE CLEAN DRY AIR THERMOMETER PERMEATION TUBE MIXING DRIER 19 ...
... adjusting the dilu- tion flow rates appropriately . The concentra- tion of SO2 in each atmosphere is calculated as follows : where : P , × 103 r C = ( 12 ) Qd + Qp NEEDLE VALVE CLEAN DRY AIR THERMOMETER PERMEATION TUBE MIXING DRIER 19 ...
Page 26
... adjustment device . Any manual adjustment device must be designed with positive detents or other means to avoid uninten- tional changes in the setting . 7.2.2 Minimum sample flow rate , heavily load- ed filter : 1.1 m3 / min ( 39 ft3 ...
... adjustment device . Any manual adjustment device must be designed with positive detents or other means to avoid uninten- tional changes in the setting . 7.2.2 Minimum sample flow rate , heavily load- ed filter : 1.1 m3 / min ( 39 ft3 ...
Page 27
... min ] ) , use a different filter , or adjust the sampler flow rate . Warning : Substantial flow adjustments may affect the calibration of the orifice - type flow indica- tors and 27 Environmental Protection Agency Pt . 50 , App . B.
... min ] ) , use a different filter , or adjust the sampler flow rate . Warning : Substantial flow adjustments may affect the calibration of the orifice - type flow indica- tors and 27 Environmental Protection Agency Pt . 50 , App . B.
Page 29
... adjusting the voltage or power supplied to the sampler . 9.3.1 A form similar to the one illustrated in Figure 5 should be used to record the cali- bration data . 9.3.2 Connect the transfer standard to the inlet of the sampler . Connect ...
... adjusting the voltage or power supplied to the sampler . 9.3.1 A form similar to the one illustrated in Figure 5 should be used to record the cali- bration data . 9.3.2 Connect the transfer standard to the inlet of the sampler . Connect ...
Other editions - View all
Common terms and phrases
actual emissions adjustment air pollution air quality air quality standards ambient air quality amount appendix applicable approved arithmetic mean average calculated calibration chapter Clean Air Act Clean Unit designation cogeneration compliance comply concentration control measures control technology determined device emis emission factor emission limitation emissions data emissions increase emissions reductions emissions trading emissions trading program emissions unit enforceable Federal filter flow rate fuel graph implementation plan inventory major modification major stationary source maximum ments monitoring nitrogen dioxide NO₂ non-EGUS nonattainment nonroad NOx Budget NOx emissions number of exceedances owner or operator ozone season PAL permit PAL pollutant particulate matter percent PLCS procedures pursuant quirements reporting requirements of paragraph reviewing authority sample period sampler sions unit SIP revision specified stack State's submit subpart sulfur dioxide temperature throughput tion tons unit's vehicle volumetric flask µg/m³