Canyon Ferry Dam and Powerplant: Technical Record of Design and Construction, Canyon Ferry Unit, Missouri River Basin Project, Constructed 1849-54United States Department of the Interior, Bureau of Reclamation, 1958 - Canyon Ferry Dam - 325 pages |
From inside the book
Results 1-5 of 11
Page xii
... Resistance - 18 - inch- Carlson 72 . 73 . thermometers 40. Structural behavior equipment - Wheat- 71. Single line metering and relaying diagram for powerplant control and station - service system Main control board in powerplant ...
... Resistance - 18 - inch- Carlson 72 . 73 . thermometers 40. Structural behavior equipment - Wheat- 71. Single line metering and relaying diagram for powerplant control and station - service system Main control board in powerplant ...
Page 59
... resistance ther- mometers is installed to record this factor . In the stress ... thermometer . Strain meter groups are located at a single elevation 3630 , on a ... thermometers to measure temperatures are placed in a systematic pattern ...
... resistance ther- mometers is installed to record this factor . In the stress ... thermometer . Strain meter groups are located at a single elevation 3630 , on a ... thermometers to measure temperatures are placed in a systematic pattern ...
Page 61
... thermometers to measure temperatures are placed in a systematic pattern in block 13. A row of thermometers is placed ... resistance of this wire varies directly with temperature and with tension . When the ends of the strain " River outie !
... thermometers to measure temperatures are placed in a systematic pattern in block 13. A row of thermometers is placed ... resistance of this wire varies directly with temperature and with tension . When the ends of the strain " River outie !
Page 66
... Resistance thermometers . The resistance thermometers are of two types - embedded and inserted . The instrument shown on the upper part of figure 39 is for permanent embedment in the mass concrete . The resistance element is an enameled ...
... Resistance thermometers . The resistance thermometers are of two types - embedded and inserted . The instrument shown on the upper part of figure 39 is for permanent embedment in the mass concrete . The resistance element is an enameled ...
Page 67
... resistance thermometer , with the exception that it is smaller in diameter and streamlined to ride over obstructions in pipes . Fifty feet of three - conductor electrical cable and 50 feet of steel fish tape are attached to the thermometer ...
... resistance thermometer , with the exception that it is smaller in diameter and streamlined to ride over obstructions in pipes . Fifty feet of three - conductor electrical cable and 50 feet of steel fish tape are attached to the thermometer ...
Common terms and phrases
axis BASIN PROJECT block 12 blockouts bolts bridge BUREAU OF RECLAMATION cable Canyon Ferry Dam circuit breaker cofferdam compressor concrete conduit construction contraction joints contractor cooling crane crete cubic dam and powerplant designed discharge diversion downstream draft tube drain drilled electrical elevation embedded equipment excavation expansion joint fault feet Figure floor flume foundation gallery furnished gantry crane girders Government camp grout guide bearing header hoist HORNFELS installed kilovolts left abutment lift liner load located maximum metal meter MISSOURI RIVER BASIN Montana Power Company operation penstock pipe placed plant plate pounds per square pozzolan pressure pumping intake relay reservoir revolutions per minute right abutment river outlet rock seal shaft spillway square inch stator stay ring steel storage structure sump sump pumps supply surface switch switchyard thrust bearing tion transformer trashrack turbine upstream valve vertical voltage wall welded wire