... abutment Type : Circular , controlled crest surmounted by a ring gate with a centerline diameter of 64 feet Crest elevation : 3,548.00 with gate lowered ; 3,560.00 with gate at maximum elevation Capacity : 50,000 second - feet with ...
... abutment Type : Circular , controlled crest surmounted by a ring gate with a centerline diameter of 64 feet Crest elevation : 3,548.00 with gate lowered ; 3,560.00 with gate at maximum elevation Capacity : 50,000 second - feet with ...
Page i
... abutment tunnel at elevation 3320 ( b ) Tunnel at elevation 3140 ( c ) Tunnel at elevation 3320 ( d ) Right abutment tunnel at elevation 3140 . 22. Spillway tunnel 23 . Diversion tunnel , Page 1 11133367 9 9 666 9 9 66 9 == 11 11 11 ...
... abutment tunnel at elevation 3320 ( b ) Tunnel at elevation 3140 ( c ) Tunnel at elevation 3320 ( d ) Right abutment tunnel at elevation 3140 . 22. Spillway tunnel 23 . Diversion tunnel , Page 1 11133367 9 9 666 9 9 66 9 == 11 11 11 ...
Page xiii
... abutment excavation and early stages of excavation for fault No. 6 . . 9. Excavation along strike of fault zone No. 6 • 10. Foundation grouting and drainage system · 11. Excavation of trench between cutoff shafts in fault zone No. 3 12 ...
... abutment excavation and early stages of excavation for fault No. 6 . . 9. Excavation along strike of fault zone No. 6 • 10. Foundation grouting and drainage system · 11. Excavation of trench between cutoff shafts in fault zone No. 3 12 ...
Page xvi
... abutment of dam foundation by use of diamond drills 223 94. Results of blasting of the 100 - foot - deep diamond drill holes on right abutment . 224 95. A 10 - cubic - yard dragline excavating sand and gravel aggregate . 96. Aerial ...
... abutment of dam foundation by use of diamond drills 223 94. Results of blasting of the 100 - foot - deep diamond drill holes on right abutment . 224 95. A 10 - cubic - yard dragline excavating sand and gravel aggregate . 96. Aerial ...
Page 1
... abutment of the dam . There are three river outlets , each 96 inches in diameter , discharging from a valve house located on the right side of the tailrace downstream from the dam . The general plan of the dam and appurtenant features ...
... abutment of the dam . There are three river outlets , each 96 inches in diameter , discharging from a valve house located on the right side of the tailrace downstream from the dam . The general plan of the dam and appurtenant features ...
Contents
193 | |
195 | |
197 | |
200 | |
206 | |
211 | |
216 | |
225 | |
41 | |
45 | |
53 | |
59 | |
67 | |
77 | |
83 | |
90 | |
96 | |
103 | |
110 | |
116 | |
119 | |
125 | |
131 | |
132 | |
137 | |
144 | |
150 | |
151 | |
153 | |
160 | |
165 | |
167 | |
173 | |
175 | |
185 | |
230 | |
232 | |
233 | |
235 | |
236 | |
237 | |
238 | |
240 | |
243 | |
244 | |
247 | |
249 | |
250 | |
252 | |
253 | |
255 | |
261 | |
267 | |
270 | |
274 | |
277 | |
281 | |
287 | |
298 | |
327 | |
330 | |
Common terms and phrases
3-phase adits amperes block BUREAU OF RECLAMATION cable circuit breaker compressor concrete Conduit connected construction contraction joints contractor control bay crane cubic DENVER designed DETAIL disconnecting switches diversion tunnel downstream draft tube drain drainage drilled electric embedded equipment excavation Expansion joint fault zone feet filtered oil Flathead River floor fly ash foundation gallery frame gantry crane gate Government camp grouting header hoist holes HORSE PROJECT-MONTANA HUNGRY Hungry Horse Dam HUNGRY HORSE PROJECT-MONTANA installed INTERIOR BUREAU Kalispell kilovolts Kips lighting located maximum METAL motor operation outlet pipes panelboard penstock percent plate pounds per square powerhouse powerplant pressure PROJECT-MONTANA HUNGRY HORSE protection pump RECLAMATION HUNGRY HORSE relay reservoir reservoir water rock seals shaft shown on figure speed spillway square inch steel storage stresses structure supply switchyard tank temperature trashrack turbine UNITED STATES DEPARTMENT upstream valve house voltage volts wall